starting from $349 USD.
Alpha-Link21000-xM can be better suited for your application and budget by selecting only the required functionality. Choose and combine from:
Flexible Industrial gateway offering either 1 or 2 RS ports with PoE, logging memory, 1 A/D input and one relay output, 3 A/D inputs and 2 relay outputs options.
· Fast processing time as no delays in transmission time of data.
· Easy to setup, Browser Based Configuration
· Accessible by up to 32 TCP master/clients devices, or connect up to 32 TCP slave/server devices.
· Supports up to 31 or 62 serial slave devices.
· Ability to Save Configurations for Backup or Loading Multiple Units.
· Support for All Modbus Function Codes.
· Support multiple languages. English, Spanish, German, Italian, French, Polish, Russian, Chinese, and Japanse.
· Handy Save/Load function allows for a completed configuration to be re-used for many other installations
· Password protection prevents unauthorized access, upload and download of configurations
· Redundant power supply, multiple possible power sources
· 1 Ethernet port and 1 or 2 RS-232/422/485 ports
· Software selectable RS-232/422/485 interface
· Cost efficient with prices starting at $349 USD to $605 for the most advanced industrial features.
Allowing the DF1 port of Allen-Bradley legacy PLC-5, SLC 5/04 /03 or Micrologix serial PLCs to be connected to a Modbus TCP Client Device.
• Fully configurable Modbus TCP/IP Server
• Move up to 100 Groups of 512 Contiguous Coils or 512 Contiguous Registers to or from your Modbus TCP/IP Client
• Support for PLC5, SLC and MicroLogix PLCs
• Connect up to 32 DF1 Serial Devices
• Effortless Browser Based Configuration, no programming software is required
• Simple data translation allows you to manipulate data as it passes between protocols
Connect ASCII Devices to Your Modbus TCP/IP PLC or HMI
Alpha-Link21000-AM can transfer data between a Modbus TCP/IP Client and an ASCII device or system. You can easily to move serial ASCII data to a Modbus TCP/IP controller.
It allows you to interrupt the ASCII data strings into meaningful data types for use in your controller.
Up to 1024 ASCII characters can be parsed into up to 50 segments. Each segment can be assigned a data type and then mapped to a user defined register or coil locations. Up to 50 segments of data on Modbus can be concatenated together and delivered as string to your TCP/IP device.
A simple way to connect your Modbus TCP/IP, RTU and ASCII Devices. NetFusion’s Modbus to Modbus TCP/IP converters provide a convenient way to move Modbus Registers and Coils between Modbus TCP/IP and Modbus RTU Network Devices.
The Alpha-Link21000 provide data transfer from between Modbus devices and controllers on different physical layers.
Highlights:
Flexible Industrial gateway offering either 1 or 2 RS ports with PoE, analog and digital I/Os options.
· Fast processing time as no delays in transmission time of data.download
· Easy to setup, Browser Based Configuration
· Provides both RTU and ASCII Encoding.
· Accessible by up to 32 TCP master/clients devices, or connect up to 32 TCP slave/server devices.
· Supports up to 31 or 62 serial slave devices.
· Ability to Save Configurations for Backup or Loading Multiple Units.
· Support for All Modbus Function Codes.
· Support multiple languages. English, Spanish, German, Italian, French, Polish, Russian, Chinese, and Japanse.
· Handy Save/Load function allows for a completed configuration to be re-used for many other installations
· Password protection prevents unauthorized access, upload and download of configurations
· Redundant power supply, multiple possible power sources
· 1 Ethernet port and 1 or 2 RS-232/422/485 ports
· Software selectable RS-232/422/485 interface
· Cost efficient with prices starting at $349 USD to $605 for the most advanced industrial features.
Gateway Configuration options:
Modbus RTU Master to Modbus TCP/IP Client: Gateway presents shared block of Modbus addresses (registers and coils). Protocols exchange data by reading/writing data to and from the shared block of data.
The router becomes a shared block of Modbus registers and coils. Either protocol is able to read or write values to and from the shared block of data.
Modbus RTU Slaves to Modbus TCP/IP Client: Transparent routing requests sent to Modbus TCP node ID to Modbus RTU network for nod with ID matching substitute table (or the same ID as a particular case)
Modbus RTU slaves are presented as Modbus TCP/IP servers. Requests sent to a Modbus TCP/IP node ID will be routed to the matching slave ID on the Modbus RTU network.
Modbus TCP/IP Servers to Modbus RTU Master:
Transparent routing of Modbus RTU packets to mapped Modbus TCP IP addresses and unit ID’s.
Modbus TCP/IP servers are presented as Modbus RTU slave. In the Gateway you define the IP address and unit ID’s of your Modbus server devices and then define what slave ID they will be mapped too.
External Master: Can Read / Write up to 64K Registers and 64K Coils In BFR3000 using RTU or ASCII Encoding
External Client (s): Can Read / Write up to 64K Registers and 64K Coils in BFR300
Maximum Number TCP Client Connections: 8
Function Codes Supported: 1,2,3,4,5,6,15,16
Number External Modbus TCP Clients Supported: 5
Mapping Unit ID Field in the Client Modbus TCP Message becomes Modbus RTU Slave Address on the Modbus Network
Number of Modbus RTU Slaves Supported: 255
Function Codes Supported: All
Number External Modbus RTU Masters Supported: 1
Mapping User Configurable Mapping Table translates RTU Slave ID to Modbus TCP Address/Unit ID Field
Number of Modbus TCP Servers Supported: 255
Function Codes Supported: All
ITEM |
Description |
1 Port / 2 Port |
Price |
AlphaLink-21000-MM-c |
Modbus RTU/ASCII to Modbus TCP gateway, |
1 port Commercial |
$289.00 |
AlphaLink-21000-MM |
Modbus RTU/ASCII to Modbus TCP gateway |
1 port, Industrial -40 to 75°C operation |
$349.00 |
AlphaLink-21000-MM-PoE |
Modbus RTU/ASCII to Modbus TCP gateway, |
1 port, Industrial -40 to 75°C operation with Power over Ethernet |
$389.00 |
AlphaLink-21200-MM-c |
Modbus RTU/ASCII to Modbus TCP gateway, |
2 ports Commercial
|
$435.00 |
AlphaLink-21200-MM |
Modbus RTU/ASCII to Modbus TCP gateway, |
2 ports, Industrial -40 to 75°C operation |
$495.00 |
AlphaLink-21200-MM |
Modbus RTU/ASCII to Modbus TCP gateway |
1 port, Industrial -40 to 75°C operation with Power over Ethernet |
$535.00 |
AlphaLink-21000 acts as a node on Modbus/TCP and Modbus RTU networks with an independently programmable ID and address.
The ADC conversion results and Digital Input state and Digital Output are presented as Modbus registers on a programmable address.
Digital outputs are isolated solid-state relays.
Max current: 1.0 A
Max voltage: 30 V
Number of channels:
NF2123xMM, NF2120xMM PoE – None
NF2121xMM – 1
NF2124xMM – 2
Software has the ability to log all or some traffic on either Ethernet or Serial network. The User can choose packets to log by node ID and network and/or by function number
LOG memory size:
NF212x2MM models – 256MByte
NF212x4MM models – 512MByte
The Table below shows estimate time to fill 256MB memory:
|
Message Generation Rate (25 Bytes) |
||||
|
1 per minute |
10 per Min |
1 per Sec |
10 per Sec |
100 per Sec |
Hours |
178957.0 |
17895.7 |
2982.6 |
298.3 |
29.8 |
Days |
7456.5 |
745.7 |
124.3 |
12.4 |
1.2 |
Model Name | RS Ports | Relays | A/D Inputs | POE | LOG Memory MB | |
Fusion-NFX21100-MM | 1 | 0 | 0 | – | 0 | |
Fusion- NFX21102-MM | 1 | 0 | 0 | – | 256 | |
Fusion-NFX21104-MM | 1 | 0 | 0 | – | 512 | |
Fusion-NFX2110-MM PoE | 1 | 0 | 0 | + | 0 | |
Fusion-NFX21200-MM PoE | 1 | 0 | 0 | + | 0 | |
Fusion-NFX21102-MM PoE | 1 | 0 | 0 | + | 256 | |
Fusion-NFX21202-MM PoE | 1 | 0 | 0 | + | 256 | |
Fusion-NFX21114-MM PoE | 1 | 0 | 0 | + | 512 | |
Fusion-NFX21204-MM PoE | 1 | 0 | 0 | + | 512 | |
Fusion-NFX21130MM | 1 | 0 | 3 | – | 0 | |
Fusion-NFX21132MM | 1 | 0 | 3 | – | 256 | |
Fusion-NFX21134MM | 1 | 0 | 3 | – | 512 | |
Fusion-NFX21130MM PoE | 1 | 0 | 3 | + | 0 | |
Fusion-NFX21130-MM PoE | 1 | 0 | 3 | + | 0 | |
Fusion-NFX21230-MM PoE | 1 | 0 | 3 | + | 0 | |
Fusion-NFX21132MM PoE | 1 | 0 | 3 | + | 256 | |
Fusion-NFX21132-MM PoE | 1 | 0 | 3 | + | 256 | |
Fusion-NFX21232-MM PoE | 1 | 0 | 3 | + | 256 | |
Fusion-NFX21134MM PoE | 1 | 0 | 3 | + | 512 | |
Fusion-NFX21134-MM PoE | 1 | 0 | 3 | + | 512 | |
Fusion-NFX21234-MM PoE | 1 | 0 | 3 | + | 512 | |
Fusion-NFX21110MM | 1 | 1 | 1 | – | 0 | |
Fusion-NFX21112MM | 1 | 1 | 1 | – | 256 | |
Fusion-NFX21114MM | 1 | 1 | 1 | – | 512 | |
Fusion-NFX21110MM PoE | 1 | 1 | 1 | + | 0 | |
Fusion-NFX21110-MM PoE | 1 | 1 | 1 | + | 0 | |
Fusion-NFX21210-MM PoE | 1 | 1 | 1 | + | 0 | |
Fusion-NFX21112MM PoE | 1 | 1 | 1 | + | 256 | |
Fusion-NFX21112-MM PoE | 1 | 1 | 1 | + | 256 | |
Fusion-NFX21212-MM PoE | 1 | 1 | 1 | + | 256 | |
Fusion-NFX21114MM PoE | 1 | 1 | 1 | + | 512 | |
Fusion-NFX21114-MM PoE | 1 | 1 | 1 | + | 512 | |
Fusion-NFX21214-MM PoE | 1 | 1 | 1 | + | 512 | |
Fusion-NFX21120MM | 1 | 2 | 0 | – | 0 | |
Fusion-NFX21122MM | 1 | 2 | 0 | – | 256 | |
Fusion-NFX21124MM | 1 | 2 | 0 | – | 512 | |
Fusion-NFX21120MM PoE | 1 | 2 | 0 | + | 0 | |
Fusion-NFX21120-MM PoE | 1 | 2 | 0 | + | 0 | |
Fusion-NFX21220-MM PoE | 1 | 2 | 0 | + | 0 | |
Fusion-NFX21122MM PoE | 1 | 2 | 0 | + | 256 | |
Fusion-NFX21122-MM PoE | 1 | 2 | 0 | + | 256 | |
Fusion-NFX21222-MM PoE | 1 | 2 | 0 | + | 256 | |
Fusion-NFX21124MM PoE | 1 | 2 | 0 | + | 512 | |
Fusion-NFX21124-MM PoE | 1 | 2 | 0 | + | 512 | |
Fusion-NFX21221-MM PoE | 1 | 2 | 0 | + | 512 | |
Fusion-NFX21200-MM | 2 | 0 | 0 | – | 0 | |
Fusion-NFX21200-MM | 2 | 0 | 0 | – | 0 | |
Fusion-NFX21202-MM | 2 | 0 | 0 | – | 256 | |
Fusion-NFX21202-MM | 2 | 0 | 0 | – | 256 | |
Fusion-NFX21204-MM | 2 | 0 | 0 | – | 512 | |
Fusion-NFX21204-MM | 2 | 0 | 0 | – | 512 | |
Fusion-NFX21200-MM PoE | 2 | 0 | 0 | + | 0 | |
Fusion-NFX21202-MM PoE | 2 | 0 | 0 | + | 256 | |
Fusion-NFX21204-MM PoE | 2 | 0 | 0 | + | 512 | |
Fusion-NFX21230-MM | 2 | 0 | 3 | – | 0 | |
Fusion-NFX21230MM | 2 | 0 | 3 | – | 0 | |
Fusion-NFX21232MM | 2 | 0 | 3 | – | 256 | |
Fusion-NFX2322-MM | 2 | 0 | 3 | – | 256 | |
Fusion-NFX21234MM | 2 | 0 | 3 | – | 512 | |
Fusion-NFX2324-MM | 2 | 0 | 3 | – | 512 | |
Fusion-NFX21230MM PoE | 2 | 0 | 3 | + | 0 | |
Fusion-NFX21232MM PoE | 2 | 0 | 3 | + | 256 | |
Fusion-NFX21234MM PoE | 2 | 0 | 3 | + | 512 | |
Fusion-NFX21210MM | 2 | 1 | 1 | – | 0 | |
Fusion-NFX21210-MM | 2 | 1 | 1 | – | 0 | |
Fusion-NFX21212MM | 2 | 1 | 1 | – | 256 | |
Fusion-NFX21212-MM | 2 | 1 | 1 | – | 256 | |
Fusion-NFX21214MM | 2 | 1 | 1 | – | 512 | |
Fusion-NFX21214-MM | 2 | 1 | 1 | – | 512 | |
Fusion-NFX21210MM PoE | 2 | 1 | 1 | + | 0 | |
Fusion-NFX21212MM PoE | 2 | 1 | 1 | + | 256 | |
Fusion-NFX21214MM PoE | 2 | 1 | 1 | + | 512 | |
Fusion-NFX21220MM | 2 | 2 | 0 | – | 0 | |
Fusion-NFX21240-MM | 2 | 2 | 0 | – | 0 | |
Fusion-NFX21222MM | 2 | 2 | 0 | – | 256 | |
Fusion-NFX21242-MM | 2 | 2 | 0 | – | 256 | |
Fusion-NFX21224MM | 2 | 2 | 0 | – | 512 | |
Fusion-NFX21244-MM | 2 | 2 | 0 | – | 512 | |
Fusion-NFX21220MM PoE | 2 | 2 | 0 | + | 0 | |
Fusion-NFX21222MM PoE | 2 | 2 | 0 | + | 256 | |
Fusion-NFX21224MM PoE | 2 | 2 | 0 | + | 512 |
AlphaLink-21000C-xM: All AlphaLink-21000 are available in "C" commercial, non Industrial option.
starting at $349 USD. more
starting at $349 USD. more
starting at $349 USD. more
Number of Ports: 1
Speed: 10/100 Mbps, Auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 kV (built-in)
Number of Ports:
AlphaLink-21100 1-port: 1 DB-9
AlphaLink-21200 2- port: 1 DB-9 and 1 Terminal Block
Physical Interfaces: Each port supports (WEB configurable)
RS-232 (Rx, Tx; Rx, Tx, RTS, CTS);
RS-422/RS485 Full Duplex (Tx+, Tx-, Rx+, Rx-, GND),
RS-485 Half Duplex (Data+, Data-, GND).
Baud Rates: 50…921,600
Data Bits: 7, 8
Stop Bits: 1, 2
Parity: None, Even, Odd
Environmental:
AlphaLink-21000 Operating Temperature: -40° to +80° C (Standard option is Industrial)
Alpha-Link-21000C: Operating temperature: 0° to +60° C (“C”: Commercial option)
Power:
Power consumption: <1.2Wt All models have redundant power inputs and 5V power output.
Only for Models AlphaLink-2120xMM PoE:
Power Input 9…30V
Power input 37…55V (recommended 48V)
Power Input 5V
PoE (Power over the Ethernet) isolated input, passive or IEEE 801.2af/at compatible.
Two redundant power Inputs 9…30V