Alpha-Link17000 Modbus TCP Gateway Converter Series

Alpha-Link21000-xM:  Modbus TCP to DF1, Modbus RTU/ASCII, ASCII Gateway Converter Series.

starting from $349 USD.

 

 

Alpha-Link21000 1 and 2 port Enhanced options:

 

Alpha-Link21000-xM can be better suited for your application and budget by selecting only the required functionality. Choose and combine from:

·      Logging memory. Enabling Alpha-Link21000 to record events in your network.  more

·      PoE (Power over the Ethernet). Adding the convenience of having data and power in a single cable.    more

·      1 A/D input and one relay. Alpha-Link21000 can activate its relay based on data input or other events.   more

·      3 A/D inputs. Enables  your device to monitor data from your network directly   more

·       2 relays. Alpha-Link21000 can be part of your control system to act according to events occuring in your network  more

Alpha-Link21000 Highlights:

 

Flexible Industrial gateway offering either 1 or 2 RS ports with PoE, logging memory, 1 A/D input and one relay output, 3 A/D inputs and 2 relay outputs options.

·         Fast processing time as no delays in transmission time of data.

·         Easy to setup, Browser Based Configuration         

·         Accessible by up to 32 TCP master/clients devices, or connect up to 32 TCP slave/server devices.

·         Supports up to 31 or 62 serial slave devices. 

·         Ability to Save Configurations for Backup or Loading Multiple Units.

·         Support for All Modbus Function Codes.

·         Support multiple languages. English, Spanish, German, Italian, French, Polish, Russian, Chinese, and Japanse.

 ·         Handy Save/Load function allows for a completed configuration to be re-used for many other installations

·         Password protection prevents unauthorized access, upload and download of configurations

·         Redundant power supply, multiple possible power sources

·         1 Ethernet port and 1 or 2 RS-232/422/485 ports

·         Software selectable RS-232/422/485 interface

·         Cost efficient with prices starting at $349 USD to $605 for the most advanced industrial features.

 

Alpha-Link21000-DM:  Modbus TCP to DF1 Gateway Converter series

more

 

Allowing the DF1 port of Allen-Bradley legacy PLC-5, SLC 5/04 /03 or Micrologix serial PLCs to be connected to a Modbus TCP Client Device.

• Fully configurable  Modbus TCP/IP Server

• Move up to 100 Groups  of 512 Contiguous Coils  or 512 Contiguous Registers to or from your Modbus TCP/IP Client

• Support for PLC5, SLC and MicroLogix PLCs

• Connect up to 32 DF1 Serial Devices

• Effortless Browser Based Configuration, no  programming software is required

• Simple data translation allows you to manipulate data as it passes between protocols

 

Alpha-Link21000-AM:  ModbAus TCP to ASCII Gateway Converter Series

more 

 

Connect ASCII Devices to Your Modbus TCP/IP PLC or HMI

Alpha-Link21000-AM can transfer data between a Modbus TCP/IP Client and an ASCII device or system.  You can easily to move serial ASCII data to a Modbus TCP/IP controller. 

It allows you to interrupt the ASCII data strings into meaningful data types for use in your controller.

Up to 1024 ASCII characters can be parsed into up to 50 segments. Each segment can be assigned a data type and then mapped to a user defined register or coil locations. Up to 50 segments of data on Modbus can be concatenated together and delivered as string to your TCP/IP device.

 

Alpha-Link21000-MM:  Modbus TCP to Modbus RTU Gateway Converter Series

more

 

A simple way to connect your Modbus TCP/IP, RTU and ASCII Devices. NetFusion’s Modbus to Modbus TCP/IP converters provide a convenient way to move Modbus Registers and Coils between Modbus TCP/IP and Modbus RTU Network Devices.

The Alpha-Link21000 provide data transfer from between Modbus devices and controllers on different physical layers.

Highlights:

 Flexible Industrial gateway offering either 1 or 2 RS ports with PoE, analog and digital I/Os options.

·         Fast processing time as no delays in transmission time of data.download

·         Easy to setup, Browser Based Configuration

·         Provides both RTU and ASCII Encoding.

·         Accessible by up to 32 TCP master/clients devices, or connect up to 32 TCP slave/server devices.

·         Supports up to 31 or 62 serial slave devices. 

·         Ability to Save Configurations for Backup or Loading Multiple Units.

·         Support for All Modbus Function Codes.

·         Support multiple languages. English, Spanish, German, Italian, French, Polish, Russian, Chinese, and Japanse.

 

·         Handy Save/Load function allows for a completed configuration to be re-used for many other installations

·         Password protection prevents unauthorized access, upload and download of configurations

·         Redundant power supply, multiple possible power sources

·         1 Ethernet port and 1 or 2 RS-232/422/485 ports

·         Software selectable RS-232/422/485 interface

·         Cost efficient with prices starting at $349 USD to $605 for the most advanced industrial features.

Gateway Configuration options:

Modbus RTU Master to Modbus TCP/IP Client: Gateway presents shared block of Modbus addresses (registers and coils). Protocols exchange data by reading/writing data to and from the shared block of data.

The router becomes a shared block of Modbus registers and coils. Either protocol is able to read or write values to and from the shared block of data.

Modbus RTU Slaves to Modbus TCP/IP Client: Transparent routing requests sent to Modbus TCP node ID to Modbus RTU network for nod with ID matching substitute table (or the same ID as a particular case)

Modbus RTU slaves are presented as Modbus TCP/IP servers. Requests sent to a Modbus TCP/IP node ID will be routed to the matching slave ID on the Modbus RTU network.

Modbus TCP/IP Servers to Modbus RTU Master: 
Transparent routing of Modbus RTU packets to mapped Modbus TCP IP addresses and unit ID’s.

Modbus TCP/IP servers are presented as Modbus RTU slave. In the Gateway you define the IP address and unit ID’s of your Modbus server devices and then define what slave ID they will be mapped too.

 

Modbus TCP Client / Modbus RTU Master Operating Mode

External Master: Can Read / Write up to 64K Registers and 64K Coils In BFR3000 using RTU or ASCII Encoding

External Client (s): Can Read / Write up to 64K Registers and 64K Coils in BFR300

Maximum Number TCP Client Connections: 8

Function Codes Supported: 1,2,3,4,5,6,15,16

 

Modbus TCP Client / Modbus RTU Slave Operating Mode

Number External Modbus TCP Clients Supported: 5

Mapping Unit ID Field in the Client Modbus TCP Message becomes Modbus RTU Slave Address on the Modbus Network

Number of Modbus RTU Slaves Supported: 255

Function Codes Supported: All

 

Modbus RTU Master / Modbus TCP Server Operating Mode

Number External Modbus RTU Masters Supported: 1

Mapping User Configurable Mapping Table translates RTU Slave ID to Modbus TCP Address/Unit ID Field

Number of Modbus TCP Servers Supported: 255

Function Codes Supported: All

 

 

ITEM

Description

1 Port / 2 Port

Price

 

AlphaLink-21000-MM-c

 

Modbus RTU/ASCII to Modbus TCP gateway,

 

1 port  Commercial

 

$289.00

 

AlphaLink-21000-MM

 

Modbus RTU/ASCII to Modbus TCP gateway

 

1 port, Industrial -40 to 75°C operation

 

$349.00

 

AlphaLink-21000-MM-PoE

 

Modbus RTU/ASCII to Modbus TCP gateway,

 

1 port, Industrial -40 to 75°C operation with Power over Ethernet

 

$389.00

 

AlphaLink-21200-MM-c

 

Modbus RTU/ASCII to Modbus TCP gateway,

 

2 ports Commercial

 

 

$435.00

 

AlphaLink-21200-MM

 

Modbus RTU/ASCII to Modbus TCP gateway,

 

2 ports, Industrial -40 to 75°C operation 

 

$495.00

 

AlphaLink-21200-MM

 

Modbus RTU/ASCII to Modbus TCP gateway

 

1 port, Industrial -40 to 75°C operation with Power over Ethernet

 

$535.00

 

ALPHA-LINK21000 Enhanced HW options:

1 or 2 ports with: 

·      Optional logging memory.

·      PoE (Power over the Ethernet) Industrial Gateways with optional ***logging memory, A/D inputs and relay outputs.

·      1 A/D input and one relay output and optional  PoE (Power over the Ethernet), logging memory

·      3 A/D inputs and optional PoE (Power over the Ethernet), logging memory

·       2 relay outputs and optional PoE (Power over the Ethernet), logging memory

 

 

 

 

Analog and Digital Inputs / Digital Outputs

 

AlphaLink-21000 acts  as a node on Modbus/TCP and Modbus RTU networks with an independently programmable ID and address.

The ADC conversion results and Digital Input state and Digital Output are presented as Modbus registers on a programmable address.

 

Analog / Digital Inputs

Analog inputs are combined with independent programmable comparator inputs.

As well as indicating threshold excess comparator may be used to send user programmable Modbus packets on the condition of input voltage which is greater or less than the programmed threshold value and /or activate/deactivate the relay(s).

Input Impedance: 501 K

ADC Bits: 12

ADC Speed: Programmable 128 SPS to 3.3 kSPS

ADC Input Range: 0…+2.5V; 0…+5V; 0…+10V; 0…10mA

Comparator Programmable Voltage: 0…11.2V

ADC and Comparator Channels:           

Digital Outputs

 

Digital outputs are isolated solid-state relays.

 

Max current: 1.0 A

Max voltage: 30 V

Number of channels:

                NF2123xMM, NF2120xMM PoE – None

                NF2121xMM – 1

                NF2124xMM – 2

 

 Data Logging

Software has the ability to log all or some traffic on either Ethernet or Serial network. The User can choose packets to log by node ID and network and/or by function number

 

LOG memory size:

                NF212x2MM models – 256MByte

                NF212x4MM models – 512MByte

 

The Table below shows estimate time to fill 256MB memory:

 

 

 

Message Generation Rate (25 Bytes)

 

1 per minute

10 per Min

1 per Sec

10 per Sec

100 per Sec

Hours

178957.0

17895.7

2982.6

298.3

29.8

Days

7456.5

745.7

124.3

12.4

1.2

 

 

 

 

Feature Selection for AlphaLink-21000-MM

Serial ports:
1
2
Analog / Digital inputs:
0
1
3
Relays
0
1
2
Power Over Ethernet
No
Yes
Logging Memory (MB)
0
256
512
       
 

Model Name

RS Ports

Relays

A/D Inputs

POE

LOG Memory MB

 

Fusion-NFX21100-MM

1

0

0

0

 

Fusion- NFX21102-MM

1

0

0

256

 

Fusion-NFX21104-MM

1

0

0

512

 

Fusion-NFX2110-MM PoE

1

0

0

+

0

 

Fusion-NFX21200-MM PoE

1

0

0

+

0

 

Fusion-NFX21102-MM PoE

1

0

0

+

256

 

Fusion-NFX21202-MM PoE

1

0

0

+

256

 

Fusion-NFX21114-MM PoE

1

0

0

+

512

 

Fusion-NFX21204-MM PoE

1

0

0

+

512

 

Fusion-NFX21130MM

1

0

3

0

 

Fusion-NFX21132MM

1

0

3

256

 

Fusion-NFX21134MM

1

0

3

512

 

Fusion-NFX21130MM PoE

1

0

3

+

0

 

Fusion-NFX21130-MM PoE

1

0

3

+

0

 

Fusion-NFX21230-MM PoE

1

0

3

+

0

 

Fusion-NFX21132MM PoE

1

0

3

+

256

 

Fusion-NFX21132-MM PoE

1

0

3

+

256

 

Fusion-NFX21232-MM PoE

1

0

3

+

256

 

Fusion-NFX21134MM PoE

1

0

3

+

512

 

Fusion-NFX21134-MM PoE

1

0

3

+

512

 

Fusion-NFX21234-MM PoE

1

0

3

+

512

 

Fusion-NFX21110MM

1

1

1

0

 

Fusion-NFX21112MM

1

1

1

256

 

Fusion-NFX21114MM

1

1

1

512

 

Fusion-NFX21110MM PoE

1

1

1

+

0

 

Fusion-NFX21110-MM PoE

1

1

1

+

0

 

Fusion-NFX21210-MM PoE

1

1

1

+

0

 

Fusion-NFX21112MM PoE

1

1

1

+

256

 

Fusion-NFX21112-MM PoE

1

1

1

+

256

 

Fusion-NFX21212-MM PoE

1

1

1

+

256

 

Fusion-NFX21114MM PoE

1

1

1

+

512

 

Fusion-NFX21114-MM PoE

1

1

1

+

512

 

Fusion-NFX21214-MM PoE

1

1

1

+

512

 

Fusion-NFX21120MM

1

2

0

0

 

Fusion-NFX21122MM

1

2

0

256

 

Fusion-NFX21124MM

1

2

0

512

 

Fusion-NFX21120MM PoE

1

2

0

+

0

 

Fusion-NFX21120-MM PoE

1

2

0

+

0

 

Fusion-NFX21220-MM PoE

1

2

0

+

0

 

Fusion-NFX21122MM PoE

1

2

0

+

256

 

Fusion-NFX21122-MM PoE

1

2

0

+

256

 

Fusion-NFX21222-MM PoE

1

2

0

+

256

 

Fusion-NFX21124MM PoE

1

2

0

+

512

 

Fusion-NFX21124-MM PoE

1

2

0

+

512

 

Fusion-NFX21221-MM PoE

1

2

0

+

512

 

Fusion-NFX21200-MM

2

0

0

0

 

Fusion-NFX21200-MM

2

0

0

0

 

Fusion-NFX21202-MM

2

0

0

256

 

Fusion-NFX21202-MM

2

0

0

256

 

    Fusion-NFX21204-MM

2

0

0

512

 

Fusion-NFX21204-MM

2

0

0

512

 

Fusion-NFX21200-MM PoE

2

0

0

+

0

 

Fusion-NFX21202-MM PoE

2

0

0

+

256

 

 Fusion-NFX21204-MM PoE

2

0

0

+

512

 

Fusion-NFX21230-MM

2

0

3

0

 

Fusion-NFX21230MM

2

0

3

0

 

Fusion-NFX21232MM

2

0

3

256

 

Fusion-NFX2322-MM

2

0

3

256

 

Fusion-NFX21234MM

2

0

3

512

 

Fusion-NFX2324-MM

2

0

3

512

 

Fusion-NFX21230MM PoE

2

0

3

+

0

 

Fusion-NFX21232MM PoE

2

0

3

+

256

 

Fusion-NFX21234MM PoE

2

0

3

+

512

 

Fusion-NFX21210MM

2

1

1

0

 

Fusion-NFX21210-MM

2

1

1

0

 

Fusion-NFX21212MM

2

1

1

256

 

Fusion-NFX21212-MM

2

1

1

256

 

Fusion-NFX21214MM

2

1

1

512

 

Fusion-NFX21214-MM

2

1

1

512

 

Fusion-NFX21210MM PoE

2

1

1

+

0

 

Fusion-NFX21212MM PoE

2

1

1

+

256

 

Fusion-NFX21214MM PoE

2

1

1

+

512

 

Fusion-NFX21220MM

2

2

0

0

 

Fusion-NFX21240-MM

2

2

0

0

 

Fusion-NFX21222MM

2

2

0

256

 

Fusion-NFX21242-MM

2

2

0

256

 

Fusion-NFX21224MM

2

2

0

512

 

Fusion-NFX21244-MM

2

2

0

512

 

Fusion-NFX21220MM PoE

2

2

0

+

0

 

Fusion-NFX21222MM PoE

2

2

0

+

256

 

Fusion-NFX21224MM PoE

2

2

0

+

512

AlphaLink-21000-xM:  Modbus TCP to DF1, Modbus RTU/ASCII, ASCII Gateway Converter Series. starting from $349 USD.

 

The AlphaLink-21000-xM are Industrial Ethernet gateways for DF1, Modbus RTU/ASCII and ASCII communications to Modbus TCP Networks. Fusion-NFX21000 Ethernet & Fieldbus gateways deliver seamless communication between fieldbus and industrial Ethernet devices. They are engineered to provide reliable protocol extensibility and seamless integration with existing network devices, and they offer a viable solution for efficiently converting data from devices that use different protocols, thus reducing the need to make expensive device purchases.

AlphaLink-21000C-xM:  All AlphaLink-21000 are available in "C" commercial, non Industrial option. 

AlphaLink-21000-DM:  Modbus TCP to DF1 Gateway Converter Series.

starting at $349 USD. more

 

 

AlphaLink-21000-AM:  Modbus TCP to ASCII Gateway Converter Series 

starting at $349 USD. more

 

AlphaLink-21000-MM:  Modbus TCP to Modbus RTU Gateway Converter Series 

 starting at $349 USD. more

 

 

AlphaLink-21000 Specifications

Ethernet:

Number of Ports: 1
Speed: 10/100 Mbps, Auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 kV (built-in)

Serial Communication:

Number of Ports: 

AlphaLink-21100 1-port: 1 DB-9

AlphaLink-21200 2- port: 1 DB-9 and 1 Terminal Block

 

Physical Interfaces: Each port supports (WEB configurable)

RS-232 (Rx, Tx; Rx, Tx, RTS, CTS);

RS-422/RS485 Full Duplex (Tx+, Tx-, Rx+, Rx-, GND),

RS-485 Half Duplex (Data+, Data-, GND).

 

Baud Rates: 50…921,600

Data Bits: 7, 8
Stop Bits:
1, 2
Parity:
None, Even, Odd

 

Environmental:

AlphaLink-21000 Operating Temperature:  -40° to +80° C (Standard option is Industrial)

Alpha-Link-21000C: Operating temperature: 0° to +60° C   (“C”: Commercial option)

Power: 

Power consumption: <1.2Wt All models have redundant power inputs and 5V power output.

Only for Models AlphaLink-2120xMM PoE:

Power Input 9…30V

Power input 37…55V (recommended 48V)

Power Input 5V

PoE (Power over the Ethernet) isolated input, passive or IEEE 801.2af/at compatible.

For Models AlphaLink-212xxMM (no PoE):

Two redundant power Inputs 9…30V

Power Input 5V